fortiswitch_system_sniffer_profile – Show packet sniffer configuration in Fortinet’s FortiSwitch
New in version 1.0.0.
Synopsis
This module is able to configure a FortiSwitch device by allowing the user to set and modify system feature and sniffer_profile category. Examples include all parameters and values need to be adjusted to datasources before usage. Tested with FOS v7.0.0
Requirements
The below requirements are needed on the host that executes this module.
ansible>=2.14
FortiSW Version Compatibility
Supported Version Ranges | |
fortiswitch_system_sniffer_profile | v7.0.0 -> latest |
Parameters
- enable_log - Enable/Disable logging for task. type: bool required: false default: False
- member_path - Member attribute path to operate on. type: str
- member_state - Add or delete a member under specified attribute path. type: str choices: present, absent
- state - Indicates whether to create or remove the object. type: str required: true choices: present, absent
- system_sniffer_profile - Show packet sniffer configuration. type: dict
- filter - Flexible logical filters for sniffer (or "none") type: str
- max_pkt_count - Maximum number of packet to be captured on the interface (1-INT_MAX). type: int
- max_pkt_len - Maximum packet length to be captured on the interface (64-1534). type: int
- profile_name - Give name to the sniffer profile. type: str
- switch_interface - Select switch-interface name on which packets are to be captured. type: str
- system_interface - Select system-interface name on which packets are to be captured. type: str
Examples
- name: Show packet sniffer configuration.
fortinet.fortiswitch.fortiswitch_system_sniffer_profile:
state: "present"
system_sniffer_profile:
filter: "<your_own_value>"
max_pkt_count: "4"
max_pkt_len: "5"
profile_name: "<your_own_value>"
switch_interface: "<your_own_value> (source switch.interface.name)"
system_interface: "<your_own_value> (source system.interface.name)"
Return Values
Common return values are documented: https://docs.ansible.com/ansible/latest/reference_appendices/common_return_values.html#common-return-values, the following are the fields unique to this module:
- build - Build number of the fortiSwitch image returned: always type: str sample: 1547
- http_method - Last method used to provision the content into FortiSwitch returned: always type: str sample: PUT
- http_status - Last result given by FortiSwitch on last operation applied returned: always type: str sample: 200
- mkey - Master key (id) used in the last call to FortiSwitch returned: success type: str sample: id
- name - Name of the table used to fulfill the request returned: always type: str sample: urlfilter
- path - Path of the table used to fulfill the request returned: always type: str sample: webfilter
- serial - Serial number of the unit returned: always type: str sample: FS1D243Z13000122
- status - Indication of the operation's result returned: always type: str sample: success
- version - Version of the FortiSwitch returned: always type: str sample: v7.0.0
Status
This module is not guaranteed to have a backwards compatible interface.