:source: fortiswitch_system_tos_based_priority.py
:orphan:
.. fortiswitch_system_tos_based_priority:
fortiswitch_system_tos_based_priority -- Configure tos based priority table in Fortinet's FortiSwitch
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
.. versionadded:: 1.0.0
.. contents::
:local:
:depth: 1
Synopsis
--------
- This module is able to configure a FortiSwitch device by allowing the user to set and modify system feature and tos_based_priority category. Examples include all parameters and values need to be adjusted to datasources before usage. Tested with FOS v7.0.0
Requirements
------------
The below requirements are needed on the host that executes this module.
- ansible>=2.16
FortiSwitch Version Compatibility
---------------------------------
.. raw:: html
| Supported Version Ranges |
| fortiswitch_system_tos_based_priority |
v7.0.0 -> 7.4.3 |
Parameters
----------
.. raw:: html
- enable_log - Enable/Disable logging for task. type: bool required: false default: False
- member_path - Member attribute path to operate on. type: str
- member_state - Add or delete a member under specified attribute path. type: str choices: present, absent
- state - Indicates whether to create or remove the object. type: str required: true choices: present, absent
- system_tos_based_priority - Configure tos based priority table. type: dict
- id - Item id. type: int required: true
- priority - Tos based priority level. type: str choices: low, medium, high
- tos - IP tos value [0-15]. type: int
Examples
--------
.. code-block:: yaml+jinja
- name: Configure tos based priority table.
fortinet.fortiswitch.fortiswitch_system_tos_based_priority:
state: "present"
system_tos_based_priority:
id: "3"
priority: "low"
tos: "7"
Return Values
-------------
Common return values are documented: https://docs.ansible.com/ansible/latest/reference_appendices/common_return_values.html#common-return-values, the following are the fields unique to this module:
.. raw:: html
- build - Build number of the fortiSwitch image returned: always type: str sample: 1547
- http_method - Last method used to provision the content into FortiSwitch returned: always type: str sample: PUT
- http_status - Last result given by FortiSwitch on last operation applied returned: always type: str sample: 200
- mkey - Master key (id) used in the last call to FortiSwitch returned: success type: str sample: id
- name - Name of the table used to fulfill the request returned: always type: str sample: urlfilter
- path - Path of the table used to fulfill the request returned: always type: str sample: webfilter
- serial - Serial number of the unit returned: always type: str sample: FS1D243Z13000122
- status - Indication of the operation's result returned: always type: str sample: success
- version - Version of the FortiSwitch returned: always type: str sample: v7.0.0
Status
------
- This module is not guaranteed to have a backwards compatible interface.
Authors
-------
- Link Zheng (@chillancezen)
- Jie Xue (@JieX19)
- Hongbin Lu (@fgtdev-hblu)
- Frank Shen (@frankshen01)
- Miguel Angel Munoz (@mamunozgonzalez)
.. hint::
If you notice any issues in this documentation, feel free to create a pull request to improve it.