:source: fortiswitch_log_disk_setting.py
:orphan:
.. fortiswitch_log_disk_setting:
fortiswitch_log_disk_setting -- Settings for local disk logging in Fortinet's FortiSwitch
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
.. versionadded:: 1.0.0
.. contents::
:local:
:depth: 1
Synopsis
--------
- This module is able to configure a FortiSwitch device by allowing the user to set and modify log_disk feature and setting category. Examples include all parameters and values need to be adjusted to datasources before usage. Tested with FOS v7.0.0
Requirements
------------
The below requirements are needed on the host that executes this module.
- ansible>=2.16
FortiSwitch Version Compatibility
---------------------------------
.. raw:: html
| Supported Version Ranges |
| fortiswitch_log_disk_setting |
v7.0.0 -> 7.4.3 |
Parameters
----------
.. raw:: html
- enable_log - Enable/Disable logging for task. type: bool required: false default: False
- member_path - Member attribute path to operate on. type: str
- member_state - Add or delete a member under specified attribute path. type: str choices: present, absent
- log_disk_setting - Settings for local disk logging. type: dict
- diskfull - Policy to apply when disk is full. type: str choices: overwrite, nolog
- drive_standby_time - Power management timeout(0-19800 sec)(0 disable). type: int
- full_final_warning_threshold - Log full final warning threshold(3-100), the default is 95. type: int
- full_first_warning_threshold - Log full first warning threshold(1-98), the default is 75. type: int
- full_second_warning_threshold - Log full second warning threshold(2-99), the default is 90. type: int
- log_quota - Disk log quota. type: int
- max_log_file_size - Max log file size in MB before rolling (may not be accurate all the time). type: int
- report_quota - Report quota. type: int
- roll_day - Days of week to roll logs. type: str choices: sunday, monday, tuesday, wednesday, thursday, friday, saturday
- roll_schedule - Frequency to check log file for rolling. type: str choices: daily, weekly
- roll_time - Time to roll logs [hh:mm]. type: str
- source_ip - Source IP address of the disk log uploading. type: str
- status - Enable/disable local disk log. type: str choices: enable, disable
- upload - Whether to upload the log file when rolling. type: str choices: enable, disable
- upload_delete_files - Delete log files after uploading . type: str choices: enable, disable
- upload_destination - Server type. type: str choices: ftp-server
- upload_format - Upload compact/text logs. type: str choices: compact, text
- upload_ssl_conn - Enable/disable SSL communication when uploading. type: str choices: default, high, low, disable
- uploaddir - Log file uploading remote directory. type: str
- uploadip - IP address of the log uploading server. type: str
- uploadpass - Password of the user account in the uploading server. type: str
- uploadport - Port of the log uploading server. type: int
- uploadsched - Scheduled upload (disable=upload when rolling). type: str choices: disable, enable
- uploadtime - Time of scheduled upload. type: int
- uploadtype - Types of log files that need to be uploaded. type: str choices: traffic, event, virus, webfilter, attack, spamfilter, dlp-archive, dlp, app-ctrl
- uploaduser - User account in the uploading server. type: str
- uploadzip - Compress upload logs. type: str choices: disable, enable
Examples
--------
.. code-block:: yaml+jinja
- name: Settings for local disk logging.
fortinet.fortiswitch.fortiswitch_log_disk_setting:
log_disk_setting:
diskfull: "overwrite"
drive_standby_time: "4"
full_final_warning_threshold: "50"
full_first_warning_threshold: "49"
full_second_warning_threshold: "49"
log_quota: "8"
max_log_file_size: "9"
report_quota: "10"
roll_day: "sunday"
roll_schedule: "daily"
roll_time: ""
source_ip: ""
status: "enable"
upload: "enable"
upload_delete_files: "enable"
upload_destination: "ftp-server"
upload_format: "compact"
upload_ssl_conn: "default"
uploaddir: ""
uploadip: ""
uploadpass: ""
uploadport: "24"
uploadsched: "disable"
uploadtime: "26"
uploadtype: "traffic"
uploaduser: ""
uploadzip: "disable"
Return Values
-------------
Common return values are documented: https://docs.ansible.com/ansible/latest/reference_appendices/common_return_values.html#common-return-values, the following are the fields unique to this module:
.. raw:: html
- build - Build number of the fortiSwitch image returned: always type: str sample: 1547
- http_method - Last method used to provision the content into FortiSwitch returned: always type: str sample: PUT
- http_status - Last result given by FortiSwitch on last operation applied returned: always type: str sample: 200
- mkey - Master key (id) used in the last call to FortiSwitch returned: success type: str sample: id
- name - Name of the table used to fulfill the request returned: always type: str sample: urlfilter
- path - Path of the table used to fulfill the request returned: always type: str sample: webfilter
- serial - Serial number of the unit returned: always type: str sample: FS1D243Z13000122
- status - Indication of the operation's result returned: always type: str sample: success
- version - Version of the FortiSwitch returned: always type: str sample: v7.0.0
Status
------
- This module is not guaranteed to have a backwards compatible interface.